Unvented Cylinder Servicing £48.00 inc vat

Information regarding cylinder servicing

 

Manufacturers of unvented water heaters recommend that you have your water heating serviced once a year, and many home insurance policies and building block management companies require this. Annual maintenance will help to keep the water heater safe and in line with the requirements of G3 building regulations relating to the hot water systems. Details of what is included in the annual service are shown below.

 

Other types of water heaters such as thermal store or combination water heaters are not required to have an annual service. For these water heaters, we offer a 'system health check', which enables us to investigate all aspects of the water heater and provide a report showing the condition of the water heater and enables you to keep on top of the maintenance.

 

If an unvented water heater has not had a regular annual service there is a possibility that the rubber seals in the safety valves will have hardened. If the seals have hardened, they will not sit back correctly in the valve and will pass water. In this instance water will be visable through the tun-dish in the discharge pipe and the valve in question will need to be replaced before damage is potentially caused. We will provide a quote for the additional work to supply and fit a replacement valve. A service for unvented water heaters includes testing safety valves, recharging pressure vessels, cleaning the pressure refuction valve, checking electrical connections and providing a service certificate.

 

Risks associated with unvented systems

 

Unvented water heaters are safe to use if installed and maintained correctly through an annual service. They incorporate three levels of safety. Thermostats that prevent the water being heated above 60-65 degrees, high level cut outs that operate when water reaches 80-85 degrees because the thermostat has failed and a temperature relief valve, which operates if both of the other safety features fail and the water reaches 90-95 degrees. In addition unvented water systems also incorporate a pressure relief valve which operates at 6-7 bar.

 

We also offer unvented cylinder service plans which include a annual service and includes all parts and labour should a problem occur with your unvented cylinder.

 

What's included with a cylinder service?

 

The following tasks will be completed with the annual cylinder service.

 

  • Expansion relief valve testing
  • Temperature and pressure relief valve testing
  • Storage tank draining as needed
  • Combination valve/pressure reduction valve stripping and line strainer cleaning
  • Pressure expansion vessel check (if so quipped)
  • Expansion vessel pressure top up
  • Leak check
  • Main and boost immersion heater and thermostat function testing
  • Main and boost immersion heater resistance check
  • Electrical ground check
  • Service record completion certificate

 

 

Office (cardiff) - 02922 218411

Email - info@thompsonservices.net

Print Print | Sitemap
Thompson Services Heating, Plumbing and Bathroom's 21 Miskin Street, Cathays, Cardiff, CF24 4AQ